CCWQZ - ACRY-COTE VINYL WALL SEALER
- MSDS: CCWQZ
- Manufacturer: KELLY MOORE PAINT CO INC
- Product Name: ACRY-COTE VINYL WALL SEALER
- National Stock Number: 8010-00N075591
Product Identification
Product ID:ACRY-COTE VINYL WALL SEALER
MSDS Date:09/20/1994
FSC:8010
NIIN:00N075591
MSDS Number: CCWQZ
Responsible Party
SAN CARLOS, CA 94070
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 415-592-8337
Cage: 0Y837
Contractor
Telephone: 650-592-8337
Cage: 0Y837
Ingredients
ETHYLENE GLYCOL (SARA 313) (CERCLA)
CAS: 107-21-1
RTECS: KW2975000
Fraction By Weight: 2.2%
OSHA PEL 50 PPM (MFR)
ACGIH TLV: C 50 PPM, VAPOR
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
PROPIONIC ACID, 2-METHYL-, MONOESTER
CAS: 25265-77-4
RTECS: UF6000000
Fraction By Weight: 1-10%
OSHA PEL N/K
ACGIH TLV: N/K
PIGMENTS SUCH AS INGS 4,5, & 6
OSHA PEL N/K
ACGIH TLV: N/K
TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS: 13463-67-7
RTECS: XR2275000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
SILICATES
OSHA PEL 10 MG/M3
ACGIH TLV: 10 MG/M3
CALCIUM CARBONATE (MARBLE) (LIMESTONE)
CAS: 1317-65-3
RTECS: EV9580000
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
3,5,7-TRIAZA-1-AZONIAADAMANTANE, 1-(3-CHLOROALLYL)-, (PAINT
CAS: 4080-31-3
RTECS: XX8450000
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:DIZZINESS, HEADACHE, NAUSEA,
CONFUSION, IRRITATION TO UPPER RESPIRATORY TRACT, UNCONSCIOUSNESS,
SKIN & EYE IRRITATION. CHRONIC:NONE KNOWN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN. SEE YOUR PHYSICIAN OFR
SPECIFIC MEDICAL OPINION REGARDING CONDITIONS.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. RESTORE BREATHING. CONSULT
PHYSICIAN. EYE:FLUSH WITH LARGE VOLUMES OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. SKIN:WIPE OFF WITH A RAG. WASH
THOROUGHLY WITH SO AP AND WATER. INGEST:CONSULT HOSPITAL EMERGENCY
ROOM OR POISON CONTROL CENTER IMMEDIATELY.
Fire Fighting
Flash Point:NONE
Extinguishing Media:NOT APPLICABLE. MEDIA SUITABLE FOR SURROUNDING FIRE
.
Fire Fighting Procedures:NONE. USE NIOSH APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE (DUE TO THE
BUILD-UP OF STEAM PRESSURE) WHEN EXPOSED TO EXTREME HEAT.
Accidental Release
Spill Release Procedures:VENTILATE AREA TO PREVENT BUILD-UP OF VAPORS.
FOR SMALL SPILLS, SOAK UP WITH ABSORBANT. FOR LARGER SPILLS, DIKE
AREA WITH ABSORBENT MATERIAL AND SCOOP UP LIQUIDS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE UPRIGHT IN SEALED CONTAINERS
AWAY FROM HEAT AND FLAME.
Other Precautions:REMOVE AND WASH CONTAMINATED CLOTHING BEFORE REUSE.
Exposure Controls
Respiratory Protection:USE A PARTICLE MAS (NIOSH APPRVD TC21C) TO AVOID
BRTHG SPRAY MIST/SANDING DUST IF LOC VENT IS ADEQ TO KEEP VAP CONCS
W/IN ACCEPTABLE (TLV) LIMS. IF LOC VENT IS NOT SUFFICIENT/WHERE
EXPOS LIMS ARE EXCE EDED, WEAR SUITABLE, PROPERLY (SUPDAT)
Ventilation:LOCAL CROSS-VENTILATION OR MECHANICAL EXHAUST SUFFICIENT TO
KEEP ALL HAZARDOUS VAPOR CONCS BELOW PRESCRIBED LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
RESP PROT:FITTED RESPIRATOR (NIOSH APPRVD TC-23C OR BETTER) FOR ORGANIC
VAPS WITH DUST FILTER AS NEEDED.
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE INGS
Vapor Density:LTR/AIR
Spec Gravity:1.2
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NOT KNOWN
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:68-73
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:MAY PRODUCE HAZARDOUS FUMES WHEN
HEATED TO DECOMPOSITION AS IN WELDING.
Disposal
Waste Disposal Methods:DISCARD IN LAND FILL IN SEALED METAL CONTAINERS
AWAY FROM HEAT AND FLAME IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.